GEA Row-Denco®: climate control for data centers with great cooling demands – flexible and efficient, with the smallest of footprints

Press Release

16. 10. 2014 The close control units in the GEA Row-Denco® series are especially suited to increase the cooling capacity of data centers and to support existing systems.

These slim close-control GEA Row-Denco® units for climate control of server rooms are installed either alongside or directly between the servers. They can be operated in networked redundancy modes.
These slim close-control GEA Row-Denco® units for climate control of server rooms are installed either alongside or directly between the servers. They can be operated in networked redundancy modes.
Installing the GEA Row-Denco® between the server racks increases the air volume cooled per hour and, in turn, the temperature gradient. These units are particularly effective for expanding capacity in existing data centers.
Installing the GEA Row-Denco® between the server racks increases the air volume cooled per hour and, in turn, the temperature gradient. These units are particularly effective for expanding capacity in existing data centers.

They provide effective heat removal matched to advanced, compact, powerful servers – and eliminate the hotspots that the servers create. The units are installed either alongside or between the servers. Their footprint is only 0.30 to 0.36 m² and they are 2100 mm high. The models in the GEA Row-Denco® series provide cooling in circulating air operation with chilled water circuit (CW version) or with a direct expansion circuit (DX version) using R410A refrigerant. The units can operate in a network with duty/standby redundancy to allow for maintenance work during operations. Since the units are installed between the racks, the air paths are shortened. The result is greater air volume cooled per hour and a higher temperature gradient. To meet all requirements of room geometry, the air flow can be guided in four directions.

The standard versions of GEA Row-Denco® units include EC fans with low power consumption. In addition, the direct expansion version includes an electronic expansion valves, offering high EER values: from 3.1 to 3.4. Installation is possible with connections from either the top or bottom of the unit.

Selection is possible among four chilled water versions and three direct expansion versions. Here, the direct expansion offer cooling duties of 10.63 kW for the smallest and 28.62 kW for the largest model, with maximum air flow of 1500 m³/h to 4200 m³/h. For chilled water versions, cooling duties of 16.14 kW to 24.60 kW are available, with airflow in these models from 2520 m³/h to 4200 m³/h. An optional feature is a solution with two separate cold-water cooling circuits, enabling redundancy within a single unit. All models in this series are intended for operation with indoor temperatures of up to 45 °C. The models cooled with chilled water are designed for relative humidity of 7 to 82 % – and for direct expansion, 7 to 53 % RH.

The direct expansion versions are intended for the standard outdoor temperature range between -15 °C and +45 °C. A special winter retrofit allows extending this range down to -35 °C. There are additional accessories, depending on the basic model. These include sensors for water and smoke, noise reduction features, interface cards, humidifiers, energy-monitoring sensors, shutoff valves, flexible water connections, floor clamp kits, and dual power supply.