Kelvion TubeLiners & Shields

Eleminate Tube Leaks

Kelvion TubeLiners & Shields

We are the leader in the technology of repairing and restoring damaged heat exchanger tubes. Whether you are dealing with leaks caused by localized erosion/corrosion at the tube ends or throughout the entire tube length, Kelvion TubeLiners & Shields can extend the life of your heat exchangers to avoid costly down-time or bundle replacement.
We are the leader in the technology of repairing and restoring damaged heat exchanger tubes. Whether you are dealing with leaks caused by localized erosion/corrosion at the tube ends or throughout the entire tube length, Kelvion TubeLiners & Shields can extend the life of your heat exchangers to avoid costly down-time or bundle replacement.

Kelvion TubeLiners & Shields

Kelvion TubeLiners & Shields

Kelvion TubeLiners & Shields

Kelvion Shields/Seals

Shields/Seals repair damaged and/or leaking tube ends and prevent unnecessary retubing or plugging. Why replace the entire tube when only the first 20-30 cm are worn? They are also commonly installed in new heat exchanger tubes to prevent damage that can lead to leaking/plugged tubes. Shields/Seals can repair/restore tubes suffering from I.D. and O.D. corrosion at inlet or outlet tube ends.

The installation is done by using two methods:

  • Mechanical Expansion
  • Full Length Hybrid Expansion
Kelvion Full-length TubeLiners

Full-Length TubeLiners are designed to restore tubes that are suffering from isolated or full-length corrosion (pitting, cracking). Leaking or damaged tubes requiring plugging are returned to service. Reduced fouling of Liners increases efficiency over plain carbon steel tubes. TubeLiners are designed into new heat exchanger builds to increase reliability and extend service life expectancy. Eliminating tube leaks in between turnarounds and avoiding emergency shutdowns to plug are proven cost savings benefits.

Kelvion Cleaning services

In cases when heat exchanger tubes are fouled or plugged with debris / solids, Kelvion offers several tube cleaning services to return the heat exchanger to original design flow conditions, including:

  • Removing mud and obstructions (Jet-brush)
  • Light scale (rotatory cutter/buffer or metal bladed cleaners)
  • Heavy duty deposits (water tube drill)

Kelvion TubeLiners & Shields

Shields/Seals details
Shields/Seals details

The Kelvion Shields/Seals technology is a thin walled metallic tube insert made of highly durable alloys. For tubes suffering from inlet-end erosion/corrosion, stress corrosion cracking, crevice corrosion or any problems related to the tube-ends, Kelvion offers its most cost-effective tube repair, the Kelvion Shields/Seals, ranging in length from 4 inches to 14 feet (100mm to 4270mm) long.

Kelvion has two methods of expansion for our Shields/Seals. Mechanical expansion involves expanding the Shield/Seal at the first inch (25mm), within the tube sheet and also the last inch (25mm), the discharge end. The mechanical expansion will effectively bridge any leak path or damage between the first and last inch (25mm) of the Shield/Seal.

Kelvion's Shields/Seals is a proven and effective repair process for problems related to inlet and outlet tube ends with I.D. or O.D. damage.

On certain Shields/Seals installations we use our hybrid expansion method which combines full-length hydraulic expansion of the Shields/Seals followed by our mechanical expansion. Hybrid expansion will eliminate the gap that may exist between the unexpanded portion of Shields/Seals and the tube. This is typically used on high temperature, high-pressure and long length applications.

Common failure mechanisms include

  • Tube-end erosion/corrosion
  • Stress corrosion cracking
  • Crevice corrosion
  • Localized pitting
  • Ammonia grooving
  • Reinforced tube-to-tube sheet joints

And Kelvion Shields/Seals can be provided in almost any alloy from “A to Z”, Admiralty Brass to Zirconium.

Full-length TubeLiners details
Full-length TubeLiners details

Heat exchanger tubes also suffer from a variety of full-length issues, such as pitting or cracking, or full-length wall loss. In this situation our Full-Length TubeLiners can be a very attractive alternative to a partial or full re-tube. The thin-walled Full Length TubeLiners are an effective way to ensure long-term reliability and can be installed into existing tubes or into NEW tubes.

How they work

The liner’s outer diameter is undersized to the parent tube’s inner diameter to enable insertion of the entire 40' to 60' liner. Prior to installation the tubes are cleaned and dried and the TubeLiners are inserted into the tubes. Using our custom-made pumps they are hydraulically expanded throughout the full length of the parent tubes. The liners are then cut, trimmed and mechanically expanded at the tube ends of each tube sheet, resulting in fully restored tubes.

Benefits

Kelvion's Full-Length TubeLiners can ensure long-term reliable, uninterrupted production on critical heat exchangers, and prevent potential shutdowns from tube leaks.

  • Restoring previously plugged, leaking tubes to service will recover failed heat exchangers and extend the heat exchanger life.
  • Corrosion resistant Full-Length TubeLiners can reduce fouling and increase efficiency.
  • Kelvion is able to perform this service as an emergency response on failed equipment in-situ.